Building a Complete Crimp Validation Strategy

Crimp validation helps ensure reliable electrical connections by proving that the complete termination system performs as intended, not merely that the correct component and tool were selected. A reliable crimp must satisfy mechanical, electrical, physical, and regulatory requirements, and no single inspection or test can confirm all of those conditions on its own. Validation creates the body of evidence needed to show that the wire, contact, tooling, process, and applicable standards work together to produce a dependable connection.

A crimp termination can look acceptable, withstand a pull test, and still fail to deliver the electrical performance required by the application. That is one of the central lessons from a recent webinar presented by Daniels Manufacturing Corporation® (DMC®) on crimp quality and validation.

During the webinar, Lexi Horvath, Kirk Koons, and John Conner examined the physical, mechanical, and electrical characteristics that determine whether a crimped connection is reliable. Their discussion explained the termination design pathway, identified common defects and causes, reviewed validation test methods, and discussed how standards define performance requirements for the application.

The Path from a Problem to a Solution

DMC organized the discussion around what it called the Crimp Quality Pathway (figure 1), a structured method for engineering and validating a tooling solution from an identified customer problem statement. It begins with the problem statement, moves to the applicable regulations or requirements, and then enters a cycle of design, validation, and iteration before arriving at a solution.

flowchart for good quality crimp validation.


Figure 1.  The Crimp Quality Pathway

That sequence is important because crimping problems are not solved simply by making an adjustment and checking whether the finished termination looks better. A manufacturer must first understand what the termination needs to accomplish and which requirements govern the connection before selecting validation methods, evaluating results, and refining the process.

The iterative portion of the pathway involves disciplined changes to wire preparation, tooling selection, crimp geometry, conductor compaction, equipment setup, and other process variables. Engineers evaluate each change against the applicable acceptance criteria. The process continues until the crimp demonstrates the required mechanical and electrical performance.

DMC’s approach also distinguishes troubleshooting from validation. Troubleshooting identifies the immediate cause of a defect and a potential solution, while validation proves that the resulting solution produces an acceptable termination consistently.

Recognizing the Different Forms of Failure

Crimp validation is complicated because poor terminations do not all fail in the same way, and the underlying causes often remain hidden. The DMC webinar grouped common crimp-quality problems into several broad categories of defects, including physical damage, mechanical failure, voltage drop, improper compaction, and arcing.

Some problems are readily visible (figure 2). Careful inspection detects cracks in the terminal or contact, broken conductors, loose strands, excessive deformation, and an incorrectly positioned crimp. These conditions indicate incorrect tooling, improper setup, poor wire preparation, excessive force, or a component mismatch among the wire, contact, and crimping system.

Figure 2. Common visual indicators of crimp defects.

Inspection is an essential first line of defense, but appearance alone cannot establish whether the crimping process compacted the strands correctly or whether the termination will maintain low electrical resistance.

Mechanical failures present another category of concern. A wire pulls out of a terminal, breaks near the crimp, or separates under loads encountered during assembly or service when the termination lacks proper conductor engagement, compression, strand integrity, or strain control.

An excessively tight crimp appears mechanically secure while damaging or weakening the conductor and reducing its ability to withstand service conditions. A loose crimp can leave the wire under-compressed, increase resistance, create internal voids that contribute to aging, and establish conditions that may lead to arcing, while showing relatively little evidence on the exterior. The location and nature of the failure provide essential clues, but they must be interpreted in the context of the complete termination.

What a Pull Test Can Tell You

Pull-force testing remains one of the most widely used methods for evaluating crimped connections. As a process validation tool, it provides useful indicators of process stability, tooling selection, and setup. The principle is straightforward: the operator applies a controlled tensile load to the wire and termination until the assembly separates or the conductor breaks, then compares the measured force at failure with the applicable requirement.

In its webinar demonstration, DMC used the company’s MPT-250C motorized pull tester. Motorized testing equipment applies the load at a controlled rate, reducing the variability manual testing can introduce (figure 3).

DMC Digital wire terminal pull tester used to measure crimp connection strength.

Figure 3.  Pull-force testing using DMC’s MPT-250C

The peak force value matters, but the failure mode tells an equally important story. Wire breaking outside the crimp can indicate a mechanically strong termination and appropriate compression, although the result must still be evaluated against the applicable test requirement. Wire pullout indicates lower compression, missing strands, or improper wire insertion. Breaking at the crimp indicates strand damage, excessive compression, or stress concentration. These outcomes provide different insights into the mechanical behavior of the termination, even when the final force exceeds the minimum prescribed value.

Pull testing provides valuable evidence of mechanical strength, especially for high-vibration and rough-use applications. It also offers a repeatable means of comparing a specimen with a defined minimum requirement. However, a passing tensile result does not prove that the connection has acceptable electrical resistance. Pull testing should therefore be understood as one component of validation, not as a universal verdict on crimp quality.

Mechanical Success Does Not Guarantee Electrical Performance

Mechanical strength supports the electrical purpose of a crimp, but it cannot replace direct evaluation of voltage drop. A crimp may achieve an acceptable pull-force value while producing an unsatisfactory electrical result.

Voltage-drop testing adds the electrical side of the validation picture (figure 4). In this method, a specified current passes through the connection, and the resulting voltage drop is measured. The allowable value depends on factors such as wire size, conductor material, plating, and the applicable specification.

Electrical voltage drop test setup with multimeter and connected test leads.

Figure 4.  Typical voltage drop test setup.

Because the expected voltage drop can be very small, the test setup and measurement technique are important. Connections, lead placement, current control, specimen preparation, and instrument capability can all influence the result. Testing must be performed according to the governing procedure if the data is to be meaningful.

An excessive voltage drop indicates unwanted resistance in the electrical path. That resistance can result from insufficient compaction, internal voids, contamination, damaged or missing strands, poor contact between conductive surfaces, or an unsuitable combination of materials and geometry.

Electrical data must be evaluated with the mechanical integrity of the termination. A connection must retain the conductor and maintain its electrical characteristics under the conditions it will encounter in service. Cross-section analysis provides further insight into internal conditions associated with unexplained mechanical or electrical failures.

Compaction Inside the Crimp

Conductor compaction affects both mechanical retention and electrical performance.

The DMC webinar compared examples of over-crimping, under-crimping, and correct compaction. In an over-crimped termination, the die or crimping geometry compresses the conductor too severely. This can deform the contact excessively, damage strands, create stress concentrations, or produce flashing and winging around the crimped area.

An under-crimped termination leaves the conductor insufficiently compacted. Individual strands retain their round shape, and air spaces remain between the strands or between the conductor and barrel. These spaces or voids contribute to thermal aging in some applications, such as aluminum wiring. The crimp also lacks adequate mechanical retention and provides less metal-to-metal contact for current transfer, increasing resistance and heat buildup.

Correct compaction occupies the functional region between these extremes. The conductor strands are compressed sufficiently to establish intimate contact without being damaged by excessive deformation. Externally, the crimp should show clean, well-defined geometry rather than uncontrolled material displacement. Internally, the strands should form a compact and consistent mass appropriate to the contact design.

The difficulty is that this internal condition cannot always be judged from the outside. That is where cross-section analysis becomes particularly valuable.

Cross Sections Reveal What the Exterior Cannot

Cross-sectioning exposes the internal structure of the termination. The evaluator cuts through the crimped area, prepares and polishes the specimen, and examines it under magnification. This allows the evaluator to see how the conductor strands, contact barrel, and crimp geometry interact.

A properly prepared cross section can reveal strand distribution, voids, incomplete compaction, excessive deformation, cracks, asymmetry, and other conditions that routine visual inspection may miss. It can also demonstrate whether the tooling applied the crimping force evenly and whether the conductor occupies the barrel as intended.

The failure examples shown by DMC illustrate why appearance can be misleading. Some sections contained visible spaces among conductor strands. Others showed uneven material flow, distorted crimp geometry, or areas in which the conductor and contact were not interacting as expected (figure 5).

Typical failures revealed by cross-section analysis.

Figure 5.  Typical failures revealed by cross-section analysis.

Cross-section analysis is especially useful during initial process validation, tooling evaluation, troubleshooting, and the investigation of unexplained electrical or mechanical results. It is destructive, so it is not a substitute for production inspection of every termination. It also requires expert analysis. Its value lies in verifying the underlying structure and helping engineers relate external measurements to internal conditions.

Together, pull-force results, voltage-drop testing, and cross-section analysis provide a more complete picture. The pull test describes mechanical behavior under load. The cross section explains why the termination behaved that way.

The Danger Behind Excessive Resistance

The DMC webinar connected excessive voltage drop or crimp resistance with one of the more serious potential consequences of a poor termination: arcing.

Electrical resistance generates heat. When a termination is loose, damaged, contaminated, or inadequately compacted, localized heating can accelerate oxidation and further degrade the connection. Movement, vibration, or intermittent contact may then allow current to jump across a gap, creating an arc (figure 6).

Electrical arcing at a bolted cable terminal connection, illustrating a potential failure in automotive electrical systems.

Figure 6.  Illustration of electrical arcing across a compromised connection.

In a low-energy application, an inadequate crimp first appears as an intermittent signal, nuisance fault, or unexplained voltage loss. In a higher-current or safety-critical circuit, the consequences include dielectric breakdown in surrounding insulation, connector housings, or adjacent components, along with accelerated aging effects. Under the wrong conditions, an electrical fault becomes a fire or personnel-safety hazard.

In power applications, insulated terminals are commonly used to reduce the risk of arcing at distribution points. Dielectric strength testing verifies that the tooling solution preserves the insulation sleeve on the terminal. If a tool pinches, tears, or thins the insulation, the reduced dielectric strength makes arcing more likely. This risk increases in high-voltage applications, where greater electrical potential places higher stress on insulating materials and nearby components.

This progression explains why crimp validation should not be treated solely as a workmanship exercise. The termination is a functional electrical component. Its geometry, materials, mechanical strength, and resistance all contribute to system performance.

Standards Establish the Target

Testing only becomes meaningful when the results are compared with the correct requirement. The DMC webinar referenced IPC/WHMA-A-620 along with several SAE aerospace specifications, including AS22520, AS7928, AS39029, AS5259, and AS50881.

These documents do not all address the same products or requirements. The applicable standard may depend on the terminal or contact, crimping tool, wire, assembly, customer specification, and intended application. Manufacturers must identify the controlling requirement before determining which inspections and tests are necessary and what constitutes an acceptable result.

This is why the Crimp Quality Pathway places regulation or requirements near the beginning rather than at the end. Standards are not paperwork applied after a process has been developed. They help define the performance target that guides design, tooling selection, testing, and validation.

A detailed comparison of the standards is beyond the scope of this article. The important point is that manufacturers should never assume that a familiar test method or internal company practice satisfies every application.

Building a Body of Evidence

The most useful conclusion from DMC’s presentation is not that one particular test is superior to another. Rather, each method answers a different question.

Visual inspection asks whether the termination shows observable defects or incorrect workmanship. Pull-force testing evaluates its ability to withstand a controlled mechanical load. Cross-sectioning reveals how the conductor and contact have been formed internally. Voltage-drop testing evaluates the electrical resistance of the completed connection. Applicable standards define the requirements against which those observations and measurements must be judged.

Reliable crimping depends on more than just producing a termination that survives the next inspection. It requires establishing why the crimp is acceptable, demonstrating that it satisfies the relevant mechanical and electrical requirements, and confirming that the process can reproduce that result.

DMC’s complete Crimp Quality and Validation Webinar is available on DMC’s YouTube channel for readers who would like to view the demonstrations and technical examples discussed in this article.

Presenters:

·  Lexi Horvath, Marketing Specialist

·  Kirk Koons, Principal Mechanical Engineer
·  John Conner, Operations Manager